Using Code Memory Weight Check Mode Condition Formula for Comparison Setpoint Comparison Description of Input parameters and Outputs Page 5: Compliance 1. Compliance Compliance Compliance Compliance 1. Compliance with FCC Rules Please note that this equipment generates, uses and can radiate radio frequency energy.

This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when this equipment is operated in a commercial environment.

Page 6: Introduction 2. Introduction Introduction Introduction Introduction The AD is a weighing indicator that amplifies signals from a load cell, converts it to digital data and displays it as a mass value. This indicator has the following performance: Input sensitivity Maximum display Page 7: Installation And Precautions 3. Installation and Precautions The weighing indicator is a precision electronic instrument. Handle it carefully. Do not install the scale in direct sunlight.

Adjustment of the Load Cell Output Caution Use a metal film resistor in the range of 50kohm to kohm with a good temperature coefficient, when adding a resistor to adjust a load cell output. Use as large of a resistance value as possible in the range in which the zero adjustment is possible. Page 9: Installing An Option Board 3. Installing an Option board Caution Do not remove any screws without the following step.

Step 1 Remove the power cord from the AC power source. Step 2 Remove eight hex bolts one of them is the sealing bolt from the rear panel. Description of Panels and symbols Description of Panels and symbols Description of Panels and symbols Description of Panels and symbols 4.

Indicates when the weight is net weight. Page Other Displays And Symbols 4. Other Displays and Symbols Standby display. Zero error when turning the display on. If the key is pressed, the current weighing value may be displayed. Over load display. Remove any load from the load cell immediately. It may cause damage to the load cell s. Example of an error display. Page Calibration 5. Calibration Calibration Calibration Calibration This indicator, converts an input voltage from a load cell to the "mass" value, and displays it.

Calibration is the adjustment function so that the scale indicator can display the weight correctly. Page Calibration Procedure Note that the key does not function alone. Page 15 Single Range Select resolution and decimal point position and format.

Specify the weighing capacity. Page Zero Calibration 5. Select a zero calibration method to adjust the zero point The adjustment method Weighing input with nothing on the To step 9 Normal way weighing unit. The numerical way to Digital input input a load cell output To step Step13 Place a mass equivalent to displayed value Maximum capacity on the weighing unit.

Page Weighing Range Function key.. The key to store the parameters temporarily. Proceed to the Cal 0 display. Step18 Press the key to turn the display off. Selecting the Division and Range Consider the following rules to design the weighing range. Rule 1 Select the division and range of each weighing range so as to fit the following inequality.

Page Gravity Compensation Function 5. Gravity C Gravity Compensation Gravity C Gravity C ompensation ompensation F F F F unction ompensation unction unction unction If the scale is used at the calibration location, it is not necessary to perform this function. EM Brochure - English. EM Manual - English. FG Brochure - English. FG Manual - English. FS-i Inc. FS-D Brochure - English.

FS-D Manual - English. FS-i Brochure - English. FS-i Manual - English. FS-i Options Manual - English. Additional Information. GF Manual - English. GH Manual - English. GP Brochure - English. GP Manual - English. GR Brochure - English. GR Manual - English. GX Manual - English. HC-i Brochure - English. HC-i Manual - English. HL-i Brochure - English.

Z Brochure - English. Z Manual - English. HR-i Manual - English. HT Brochure - English. HT Calibration Manual - English. HT Manual - English. CE Declaration HT The weighing indicator is a precision electronic instrument. Handle it carefully. Mis-operation or other problems may be caused by an unstable power source including momentary power failure or instantaneous noise.

Use a stable power source. Do not connect the power cord before the installation has been completed. Verify that the local voltage and receptacle type are correct for your scale.

Use shielded cable for all connections. Connect the cable shields to the shield terminal or case as an earth terminal. Earth ground the indicator. Do not join the earth ground line with other electrical power equipment. Example: There is an earth ground terminal at the power cord receptacle.

Plastic and insulating materials are apt to be charged with static electricity. The Load Cell Connections. It is possible to connect a 4 wire cable provided that pins and pins are shorted, if the distance between the indicator and a load cell is shorter than 5m. The output voltage of a load cell is a very sensitive signal. Space the load cell cable away from any noise source. Adjustment of the Load Cell Output. Caution Use a metal film resistor in the range of 50kohm to kohm with a good temperature coefficient, when adding a resistor to adjust a load cell output.

Use as large of a resistance value as possible in the range in which the zero adjustment is possible. Solder this resistor at a point near the load cell or the indicator. The input sensitivity of the indicator is 0. Adapt to the following. A: Rated capacity of load cell [kg]. Installing an Option board. Remove the rear panel carefully as there are cables between the front unit and the. Place the rear panel on the front unit, and secure using the bolts removed in Step 2.

Front Panel Description. Rear Panel Description. Other Displays and Symbols. Zero error when turning the display on. If the ESC key is pressed, the current weighing value may be displayed.

Over load display. Remove any load from the load cell immediately. It may cause damage to the load cell s. Accessories and Options. One option can be installed at a time, by exchanging with the standard RSC interface.

This indicator, converts an input voltage from a load cell to the "mass" value, and displays it. Calibration is the adjustment function so that the scale indicator can display the weight correctly. Items of Calibration Mode. How to calibrate: In weighing mode, press the CAL key. After Cal in is displayed. However, in some cases, the procedures are altered to nullify this. Furthermore, this option is not available with Stamping type version setting.

Compensates for acceleration of gravity. Configuring a Weighing Instrument. This section explains how to specify capacity, resolution, decimal point position and display format, weighing range and unit.

Perform this procedure when installing the indicator. Specify the range and unit. Step 2 The resolution will be displayed as d The indicator displays triangle 1 and the first unit selected at the previous step. Specify the position of the decimal point with the MODE key. The decimal point format is specified in step.

The decimal point format for serial data output is selected using the F-function settings. When pressing the ESC key, regardless of what is displayed, the indicator will proceed to the next step without changing them.

Step 3 After displaying Cap for 2 seconds, single range or the weighing capacity will be displayed. When dual range is used, Cap1 is displayed for 2 seconds. Triangle 1 will be displayed. When pressing the ESC key, regardless of what is displayed, the indicator will proceed to the next step without changing it.

The next step is Zero Calibration in single range or the second range resolution in dual range. Step 4 After displaying range2 for 2 seconds, the resolution with decimal point and triangle 2 will be displayed.

Specify the second range resolution in the same way as the first range. The decimal point cannot be moved.

Specify the second range resolution greater than the first range. Step 5 After displaying Cap2 for 2 seconds, the capacity with unit and decimal point is displayed.

Specify the capacity in the same way as the first range. The capactity should be greater than the first range. When pressing the ESC key, regardless of what is displayed, the indicator will proceed to the next step without changing the parameter.

To Get Stabilized Data. Step 6 Maintain the following conditions to calibrate the scale indicator correctly. Maintain a constant temperature, stable power and stable input voltage from the load cell. Step 9 Place nothing on the weighing unit. The new zero point parameter will be stored. Proceed to step ESC key The key not to change the zero point data and proceed to the next step.

Arrange the condition using the F00 filter function. Adjust the input voltage using the 0 - 9 keys. ESC k ey The key to proceed to the next step without changing the parameter. Step11 Check the capacity display after Cal f is displayed for 2 seconds. Step12 Specify a mass value using 0 - 9 keys. Step13 Place a mass equivalent to displayed value on the weighing unit. Proceed to step It is possible to store a greater value than the capacity.

ENTER key The key to store the span parameters and proceed to step The key to proceed to step 17 without changing the span parameters. Exiting the Calibration Mode. The key to store the parameters temporarily.

Proceed to the Cal 0 display. CanCel is displayed and the calibration mode is finished. The weighing range function can select "single range" and "dual range". Specify each weighing interval division for the multi-interval instrument. Each weighing interval is displayed according to a net value or gross value.

Selecting the Division and Range. Rule 1 Select the division and range of each weighing range so as to fit the following inequality.

The division of the next weighing range is automatically set larger than the division of the lower weighing range. And the division can change. Rule 2 When specifying the dual range, the upper limit value of the second range becomes the maximum capacity. Rule 3 Select a resolution smaller than The resolution is a value that divides the maximum capacity by the minimum division of the first range. Even if the zero and span calibration have been completed, there may still remain a linearity deviation caused by the performance of the weighing unit.

The digital linearization function can rectify or reduce the linearity deviation using weighing points during the zero and capacity. Up to three weighing points can be specified. Select a middle point value using the 0 - 9 keys.

Proceed to step 5. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox.

Please check your email for further instructions. Enter a new password. Page 2 AD Weighing Indicator. This indicator has the following performance: Input sensitivity Maximum display Refresh rate of the display Input voltage range The setpoint comparison for batching applications. The counting function for piece counting.